Prediction of Vibration Vibro Replacement (TRL)    1/1, 1/3

An initial estimate of possible vibration levels arising from vibro replacement (vibrating stone column) activities can be obtained from the following equation:

`\nu_(res)=k_c/x^(1.4)`
where:

Source: Transport Research Laboratory Report 429 Groundborne vibration caused by mechanised construction works (2000), Equation 22